top of page

MicroCal PEAQ-ITC

Description

Malvern Panalytical

Malvern Panalytical

MicroCal PEAQ-ITC The Gold Standard for measuring affinity and stoichiometry The MicroCal PEAQ-ITC is a highly sensitive, low volume isothermal titration calorimeter for the label-free in solution study of biomolecular interactions. It delivers direct measurement of all binding parameters in a single experiment and can analyze weak to high affinity binders, using as little as 10µg sample. Semi-automated maintenance minimizes operator intervention and the system is upgradable to the fully automated MicroCal PEAQ-ITC Automated, making it ideal for laboratories where speed, sensitivity and the ability to accommodate higher workloads in the future are paramount.

Key Differences

< click here

MicroCal PEAQ-ITC is designed for ease-of-use and exceptional sensitivity. The system directly measures heat released or absorbed during biochemical binding events, from which it calculates binding affinity (KD), stoichiometry (n), enthalpy (ΔH), and entropy (ΔS). With minimal sample preparation and system optimization data is generated quickly and easily. The wide affinity range enables analysis of weak to high affinity binders, with excellent reproducibility. MicroCal ITC is an essential tool for any research laboratory studying biomolecular interactions where high sensitivity and fast results are paramount.

  • User-friendly guided workflows with embedded help videos give any level of user the ability to generate high quality data.

  • High signal to noise gives more confidence in accessing data quality and relevance of generated affinity and thermodynamic parameters.

  • Automated washing with detergent of the sample cell and titration syringe assists in producing high quality reproducible data.

  • All binding parameters (affinity, stoichiometry, enthalpy and entropy) in a single experiment.

  • Quick to first results with no assay development, no labeling, no immobilization and no molecular weight limitations.

  • Sensitivity to investigate any biomolecular interaction using as little as 10µg of protein.

  • Directly measures millimolar to nanomolar affinities (KDS) (10-2 to 10-9 M).

  • Measures nanomolar to picomolar disassociation constants using competitive binding techniques (10-9 to 10-12M).

  • Nonreactive Hastelloy for chemical resistance and compatibility with biological samples.

  • Compatible with non-aqueous solvents.

  • Upgradable to fully automated MicroCal PEAQ-ITC Automated.

A wide range of applications can be investigated with MicroCal PEAQ-ITC, including characterization of molecular interactions of small molecules, proteins, antibodies, nucleic acids, lipids and other biomolecules. It can also be used to measure enzyme kinetics. 

MicroCal PEAQ-ITC analysis software offers experiment design simulation, batch evaluation of large data sets, automated assessment of data quality and a streamlined user interface that guides the user to final figures and presentation quality graphs quickly and easily.

  • Open multiple experiments in a single session.

  • Supports many automated fitting models.

    • Dissociation.

    • Enzyme Kinetics - Multiple Injections.

    • Enzyme Kinetics - Single Injection.

    • One Set of Sites.

    • Sequential Binding Sites.

    • One Set of Sites - SIM.

    • Two Sets of Sites.

    • Competitive.

  • Automated assessment of data quality.

    • Good quality data – Binding.

    • Good quality data - No binding.

    • Poor quality data – Check data.

Technical Specification

< click here

Measurement type: Affinity (KD)

Measurement type: Enthalpy ∆H

Measurement type: Entropy ∆S

Measurement type: Stoichiometry (n)

Sample volume: 280 µL

Cell volume: 200 µL

Injection syringe volume: 40 µL

Injection volume precision: < 1% @ 2 µL

Sample throughput: 0-12 per 8 h day

Cell material: Hastelloy

Cell: Coin-shaped

Noise: 0.15 ncal/s

Temperature range: 2°C to 80°C

Temperature stability: ± 0.00012°C

Response time: 8 s*

Multiple feedback modes: Yes (passive, high gain, low gain)

Notes:

*The MicroCal PEAQ-ITC Instrument Response Time is a true time constant.  It is the time interval between the first deviation away from the baseline, and the point on the peak that is 63% of the maximum peak height.

 

Operating Environment

Temperature (operating): 10°C to 28°C

Humidity: 0% to 70% RH, non condensing

 

Electrical ratings

Power: 100 - 200 V, 50/60 Hz, 130 W

Weight: 13.6 kg

Dimensions (W, D, H): 43 x 38 x 46 cm (calorimeter + wash station)

MicroCal PEAQ-ITC

Downloads

Related Products

MicroCal PEAQ-ITC Automated
MicroCal PEAQ-DSC Automated
MicroCal PEAQ-ITC Automated