Dual 24

BY
SepareCo
SepareCo

Description

Dual 24+24 L system, Stainless Still frame (WxDxH) 3.2m x 1.8m x 2.2m.

Key Differences

SCFN P-20CD/PLC

Size and weight: The frame, the vessels and the pipings are completly built with stainless steel, the total structure has got these sizes: Wide 3,2 m (10.4 feet), Height 2,2 cm (7.2 feet), Deep 1,8 cm (6 feet). The Weight of the machinery is 2300 kg (5070 pounds). For this features we reccommend Room sizes of 6x5,2 m (20x17feet) and Height of 4 m (13 feet).

Main Characteristics: This machine is certified with CE or UL Certified Enclosure, and these are some of the most important technical specifications: Voltage 460 AC-V or 400 AC-V, Frequency 60 Hz or 50 Hz, Installed Power 16 kW, Current 27,5 A.

Configurations: This machine is composed by two pumps, one for CO2 and another one for co-solvent, two extraction vessels, three separation vessels and separeted chiller and heater. It can reach max pressure (Pmax) of 350 bar and max temparature (Tmax) of 85 °C. There are two pressure set-points: the first one is for extraction vessels, and the second one for separation vessels. There are 5 pressure gauges and voltage can be chosen on request.
Carbon dioxide is continually recycled with a close circuit for fluid recirculation. PLC on board, the system is connected with internet by an ethernet network connection, it's full automatic and it's equipped with touch screen and it's PED/CE or ASME/UL certified.

Pumps: There are two pumps, the most important is the CO2 pump, the carbon dioxide is the principal solvent for the extraction of apolar chemical compounds; and the secondary pump, witch is used for the contemporary release in the process of polar or medium apolar co-solvents, usefull for the extraction of chemical coumpounds with different degrees of polarity. At the condiction of max pressure this pumps can ensure  a CO2 Flow of 100 kg/h, and Co-solvent Flow of 10 L/h.

The extraction process is based on small variations of solvent's (CO2) pressure and temperature. These critical operations are ensured by some heater exchangers, fuelled by water witch is heated or cooled by separeted and external Chiller and Heater. Also these components have some technical specifications like:
Chiller: Voltage/Frequency 3 Ph 460/60 V/Hz or 400/50 V/Hz, Installed Power 8,98/14 kW/A, Size (WxHxD) 60x130x140 cm (2x4,2x4,6 feet).
Heater: Voltage/Frequency 3 Ph 460/60 V/Hz or 400/50 V/Hz, Installed Power 12,7/19,9 kW/A, Size (WxHxD) 30x55x75 cm (1x1,8x2,4 feet), Water connection in/out 1¼"x1" M.

Technical Specification

Vessels Volumes:
Extractor volume 1 & 2: 24 L
Extraction basket volume 1 & 2: 20 L
Separator 1 volume: 5 L
Separators 2 & 3 volumes: 3 L
Accumulator volume: 40 L

Other specifications:
ASME certified safety valve for each vessel in isolated tubing from vessel.
Low headroom hoist
Touch screen size 15 inch.
PLC microprocessor Intel i7
Compressed air pressure 100 Ψ
Compressed air flow 1 CFM/h
2 Back pressure automatic pilot valves
2 Automatic back pressure valves

SCFN P-20C/PLC

There's also the option with only one extraction vessel with 24 L of volume and 20 L of basket volume.

Dual 24

Downloads

Related Products

Dual/Triple 51
Dual 12